NYFGbY  IEC 60502 -  1  0,6 / 1kV

  BACK

APPLICATION PLACE TECHNICAL DATA
These cables are used in the place where
has hard mechanical conditions,
underground installation, in power and
switching stations.If it is specially produced.
it can be used in freshwater and seawater.

Maximum working temperature: 70°C
Short circuit temperature: 160°C
(Max for 5 Sec.)
Rated Voltage: Uo/U - 0,6 / 1 kV
Test Voltage : 3,5 kV ( AC )
Bending Radius : 12 x D
Size and Weights Electrical Specification
Nominal cross section Overall diameter approx. Net weight approx. Standard delivery lenght Type of packing, coil or drum size Conductor DC resistance at 20°C max. Current carrying capacity
In ground 20°C max. In air 30°C max.
mm2 mm kg/km m cm ohm/km A A
3x16 24.0 1300 1000 141 1.15 98 80
3x25 28.0 1830 1000 141 0.727 128 106
3x35 31.0 2290 1000 141 0.524 157 131
3x50 33.0 2760 1000 161 0.387 185 159
3x70 37.0 3360 1000 201 0.268 228 202
3x95 42.0 4770 1000 221 0.193 275 244
3x120 45.0 5690 500 161 0.153 313 282
3x150 50.0 6860 500 201 0.124 353 324
3x185 54.0 8210 500 221 0.0991 399 371
3x240 62.0 10810 250 201 0.1754 464 436
3x300 68.0 13210 250 201 0.0601 524 481
3x400 76.0 16490 250 221 0.0470 600 560
3x25+16 30.0 2080 1000 161 0.727 128 106
3x35+16 32.0 2500 1000 161 0.524 157 131
3x50+25 34.0 3080 1000 161 0.387 185 159
3x70+35 39.0 4090 1000 201 0.268 228 202
3x95 +50 44.0 5290 1000 221 0.193 275 244
3x120+70 48.0 6530 500 181 0.153 313 282
3x150+70 52.0 7680 500 201 0.124 353 324
3x185+95 57.0 9330 500 221 0.0991 399 371
3x240+120 64.0 12010 250 201 0.0754 464 436
3x300+150 70.0 14720 250 221 0.0601 524 481
3x400+185 78.0 184430 250 221 0.0470 600 560
         NYFGbY  IEC 60502 -  1  0,6 / 1kV
APPLICATION PLACE TECHNICAL DATA
These cables are used in the place where
has hard mechanical conditions,
underground installation, in power and
switching stations.If it is specially produced.
it can be used in freshwater and seawater.

Maximum working temperature: 90°C
Short circuit temperature: 250°C
(Max for 5 Sec.)
Rated Voltage: Uo/U - 0,6 / 1 kV
Test Voltage : 3,5 kV ( AC )
Bending Radius : 12xD
Size and Weights Electrical Specification
Nominal cross section Overall diameter approx. Net weight approx. Standard delivery lenght Type of packing, coil or drum size Conductor DC resistance at 20°C max. Current carrying capacity
In ground 20°C max. lnair30°Cmax.
mm2 mm kg/km m cm ohm/km A A
4x16 26.0 1580 1000 141 1.15 98 80
4x25 30.0 2210 1000 161 0.727 128 106
4x35 33.0 2760 1000 161 0.524 157 131
4x50 36.0 3390 1000 161 0.387 185 159
4x70 41.0 4520 1000 221 0.268 228 202
4x95 46.0 5860 500 161 0.193 275 244
4x120 51.0 7170 500 201 0.153 313 282
4x150 55.0 8590 500 221 0.124 353 324
4x185 60.0 10380 500 221 0.0991 399 371
4x240 68.0 13430 250 201 0.1754 464 436
4x300 75.0 16410 250 221 0.0601 524 481
4x400 84.0 20550 250 241 0.0470 600 560
     
         NYFGbY
  IEC 60502 / -  1  0,6 / 1kV

˄ TOP