Euro Cable Private Limited Company, an Ethio-Turkish joint venture established in May 2007, is the first private manufacturer of electrical cables in Ethiopia.
DATA & COAXIAL CABLES
POWER CABLES
FLEXIBLE CABLES
BUILDING WIRES
APPLICATION PLACE
These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 125 Mbit/sn.
CONSTRUCTION
Solid conductor of bare copper wire (0.51 mm), Polyelefin insulation. Cores twisted in pairs, four screened pairs twisted in layers. PVC compound or HF Compound outer sheath, gray.
TECHNICAL DATA
- Impedance             Â100 Ω±%15 in range of 1-100 MHz
-
-
-
-
- 100 Ω±%22 in range of 125 MHz
-
-
-
-
- Mutual Capacity        ÂMax. 56 nF/km (at 1 kHz)
- Velocity Ratio          ÂMax. 94.Ω/km
- Insulation Resistance   ÂMin. 5000 MW.km
- Working Temperature  Â-30°C to + 70°C
- Working Voltage        Â250 volt
- Test Voltage            Â1200 volt
- Min. Bending Radius    Â25 mm
APPLICATION PLACE
Used as connection cable in aerial distributions of CATV, CCTV and Satellite TV systems.
CONSTRUCTION
Electrolitic annealed copper wire. Foam polyethylene insulation. Screen of plastic coated copper tape (100% coverage). Screen braiding of annealed copper wire (65% coverage). Outer sheath of PVC compound, black.
TECHNICAL DATA
- Impedance 75 ± 3 Ω
- Mutual Capacity 54 pF/m
- Velocity Ratio 0.82
- Insulation Resistance >2000 M Ω km
- Working Temperature -40°C to +70°C
- Working Voltage 2.0 kV
- Test Voltage 5.0 kV
- Min. Bending Radius 10xD
APPLICATION PLACE
Used as connection cable in indoor CATV, CCTV and Satellite TV systems.
CONSTRUCTION
Electrolitic annealed copper wire. Foam polyethylene insulation. Screen of plastic coated aluminum tape (100% coverage). Screen Braiding of tinned copper wire (60% coverage), outer sheath of PVC compound, black.
TECHNICAL DATA
- Impedance 75 ± 3 Ω
- Mutual Capacity 54 pF/m
- Velocity Ratio 0.82
- Insulation Resistance >2000 M Ω km
- Working Temperature -40°C to +70°C
- Working Voltage 2.0 kV
- Test Voltage 5.0 kV
- Min. Bending Radius 10xD
APPLICATION PLACE
Used as connection cable in CATV, CCTV and Satellite TV systems.
CONSTRUCTION
Electrolitic annealed copper wire conductor. Foam polyethylene insulation. Screen of plastic coated copper tape (100% coverage). Screen braiding of annealed copper wire (53% coverage). Outer sheath of PVC compound, black/green.
TECHNICAL DATA
- Impedance 75 ± 3 Ω
- Mutual Capacity 54 pF/m
- Velocity Ratio 0.82
- Insulation Resistance >2000 M Ω km
- Working Temperature -40°C to +70°C
- Working Voltage 1.3 kV
- Test Voltage 3.0 kV
- Min. Bending Radius 10xD
APPLICATION PLACE
Used as connection cable in CATV, CCTV and Satellite TV systems.
CONSTRUCTION
Electrolitic annealed copper wire conductor. Foam polyethylene insulation. Screen of plastic coated aluminum tape (100% coverage). Screen braiding of tinned copper wire (54% coverage). Outer sheath of PVC compound, white.
TECHNICAL DATA
- Impedance 75 ± 3 Ω
- Mutual Capacity 57 pF/m
- Velocity Ratio 0.78
- Insulation Resistance >2000 M Ω km
- Working Temperature -40°C to +70°C
- Working Voltage 1.3 kV
- Test Voltage 3.0 kV
- Min. Bending Radius 10xD
APPLICATION PLACE
Used as connection cable in CATV, CCTV and Satellite TV systems.
CONSTRUCTION
Electrolitic annealed copper wire. Foam polyethylene insulation. Screen of plastic coated copper tape (100% coverage). Screen Braiding of annealed copper wire (60% coverage). Outer sheath of PVC compound, white.
TECHNICAL DATA
Impedance 75 ± 3 Ω
Mutual Capacity 54 pF/m
Velocity Ratio 0.82
Insulation Resistance >2000 M Ω km
Working Temperature -40°C to +70°C
Working Voltage 1.1 kV
Test Voltage 2.5 kV
Min. Bending Radius 10xD
APPLICATION PLACE
These cables are used in indoor / outdoor places, in cable ducts, underground Installation, in the place where have on mechanical damage risk, in power plants, in industrial plants and switching stations. If it is specially produced, it can be used in freshwater and seawater.
TECHNICAL DATA
Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Blending Radius: 12 x D
APPLICATION PLACE
Cables are applied for power distribution in networks, industrial plants and on the places where mechanical damages are expected. Suitable for indoor and outdoor installations and direct burial.
TECHNICAL DATA
Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D
Smoke Emission: EN61034-2
Acid Gas Emission: EN50267-2-1
Flame Propagation: EN60332-1-2
NHBH IEC 60502 – 0,6 / 1kV
APPLICATION PLACE
Cables are applied for power distribution in networks, industrial plants and on the places where mechanical damages are expected. Suitable for indoor and outdoor installations and direct burial.
TECHNICAL DATA
Maximum working temperature: 90°C
Short circuit temperature: 250°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D
N2XBY IEC 60502 – 0,6 / 1kV
APPLICATION PLAC
Cables are applied for power distribution in networks, industrial plants and on the places where mechanical damages are expected. Suitable for indoor and outdoor installations and direct burial.
TECHNICAL DATA
Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D
NYBY IEC 60502 – 0,6 / 1kV
APPLICATION PLACE
These cables are used in the place where has hard mechanical conditions, underground installation, in power and
switching stations. If it is specially produced. it can be used in freshwater and seawater.
TECHNICAL DATA
Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D
Smoke Emission: EN61034-2
Acid Gas Emission: EN50267-2-1
Flame Propagation: EN60332-1-2
APPLICATION PLACE
These cables are used in the place where has hard mechanical conditions, underground installation, in power and
switching stations. If it is specially produced. it can be used in freshwater and seawater.
TECHNICAL DATA
Maximum working temperature: 90°C
Short circuit temperature: 250°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D