Euro Cable Private Limited Company, an Ethio-Turkish joint venture established in May 2007, is the first private manufacturer of electrical cables in Ethiopia.

DATA & COAXIAL CABLES

POWER CABLES

FLEXIBLE CABLES

BUILDING WIRES

APPLICATION PLACE

These connection cables are used in telecommunication networks for transmission of either analog or digital signals. Maximum working transmission speed 125 Mbit/sn.

CONSTRUCTION

Solid conductor of bare copper wire (0.51 mm), Polyelefin insulation. Cores twisted in pairs, four screened pairs twisted in layers. PVC compound or HF Compound outer sheath, gray.

TECHNICAL DATA

APPLICATION PLACE

Used as connection cable in aerial distributions of CATV, CCTV and Satellite TV systems.

CONSTRUCTION

Electrolitic annealed copper wire. Foam polyethylene insulation. Screen of plastic coated copper tape (100% coverage). Screen braiding of annealed copper wire (65% coverage). Outer sheath of PVC compound, black.

TECHNICAL DATA

APPLICATION PLACE

Used as connection cable in indoor CATV, CCTV and Satellite TV systems.

CONSTRUCTION

Electrolitic annealed copper wire. Foam polyethylene insulation. Screen of plastic coated aluminum tape (100% coverage). Screen Braiding of tinned copper wire (60% coverage), outer sheath of PVC compound, black.

TECHNICAL DATA

APPLICATION PLACE

Used as connection cable in CATV, CCTV and Satellite TV systems.

CONSTRUCTION

Electrolitic annealed copper wire conductor. Foam polyethylene insulation. Screen of plastic coated copper tape (100% coverage). Screen braiding of annealed copper wire (53% coverage). Outer sheath of PVC compound, black/green.

TECHNICAL DATA

APPLICATION PLACE

Used as connection cable in CATV, CCTV and Satellite TV systems.

CONSTRUCTION

Electrolitic annealed copper wire conductor. Foam polyethylene insulation. Screen of plastic coated aluminum tape (100% coverage). Screen braiding of tinned copper wire (54% coverage). Outer sheath of PVC compound, white.

TECHNICAL DATA

APPLICATION PLACE

Used as connection cable in CATV, CCTV and Satellite TV systems.

CONSTRUCTION

Electrolitic annealed copper wire. Foam polyethylene insulation. Screen of plastic coated copper tape (100% coverage). Screen Braiding of annealed copper wire (60% coverage). Outer sheath of PVC compound, white.

TECHNICAL DATA

Impedance 75 ± 3 Ω
Mutual Capacity 54 pF/m
Velocity Ratio 0.82
Insulation Resistance >2000 M Ω km
Working Temperature -40°C to +70°C
Working Voltage 1.1 kV
Test Voltage 2.5 kV
Min. Bending Radius 10xD

APPLICATION PLACE

These cables are used in indoor / outdoor places, in cable ducts, underground Installation, in the place where have on mechanical damage risk, in power plants, in industrial plants and switching stations. If it is specially produced, it can be used in freshwater and seawater.

TECHNICAL DATA

Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Blending Radius: 12 x D

APPLICATION PLACE

Cables are applied for power distribution in networks, industrial plants and on the places where mechanical damages are expected. Suitable for indoor and outdoor installations and direct burial.

TECHNICAL DATA

Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D
Smoke Emission: EN61034-2
Acid Gas Emission: EN50267-2-1
Flame Propagation: EN60332-1-2

NHBH IEC 60502 – 0,6 / 1kV

APPLICATION PLACE

Cables are applied for power distribution in networks, industrial plants and on the places where mechanical damages are expected. Suitable for indoor and outdoor installations and direct burial.

TECHNICAL DATA

Maximum working temperature: 90°C
Short circuit temperature: 250°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D

N2XBY IEC 60502 – 0,6 / 1kV

APPLICATION PLAC

Cables are applied for power distribution in networks, industrial plants and on the places where mechanical damages are expected. Suitable for indoor and outdoor installations and direct burial.

TECHNICAL DATA

Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D

NYBY IEC 60502 – 0,6 / 1kV

APPLICATION PLACE

These cables are used in the place where has hard mechanical conditions, underground installation, in power and
switching stations. If it is specially produced. it can be used in freshwater and seawater.

TECHNICAL DATA

Maximum working temperature: 70°C
Short circuit temperature: 160°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D
Smoke Emission: EN61034-2
Acid Gas Emission: EN50267-2-1
Flame Propagation: EN60332-1-2

APPLICATION PLACE

These cables are used in the place where has hard mechanical conditions, underground installation, in power and
switching stations. If it is specially produced. it can be used in freshwater and seawater.

TECHNICAL DATA

Maximum working temperature: 90°C
Short circuit temperature: 250°C (Max for 5 Sec.)
Rated Voltage: Uo/U – 0,6 / 1 kV
Test Voltage: 3.5 kV (AC)
Bending Radius: 12 x D